Advantay Low Loss Header / Hydraulic Separator serves primarily to divide the primary and secondary circuit
hydraulically in the heating system and to compensate for differences in flow rate and pressure drop.
They are often used in air source heat pump installations to provide a small volume of stored hot water.
Additionally a new dirt separation filter inside improves waste removal, and allows any trapped air to be removed from the top.
Now fitted as standard with an automatic air release valve and drain valve, along with 2 x 1/2” front mount connections (capped off) for use with pressure / temperature sensors / monitoring.
The Low Loss Header can be supplied as standard with a closed cell PE insulated pre-formed case, with Velcro fixing.
Manufactured from Fe360 steel epoxy powder coated.
Product Code |
Connection |
Height |
Flow Rate |
Insulation |
Max KW* |
Max °c |
Max Bar |
AD3160001 |
1″ F x 4 |
560mm |
2500 ltr/h |
YES |
43.5 |
100°c |
10bar |
AD3160002 |
1-1/4″ F x 4 |
560mm |
4000 ltr/h |
YES |
69.6 |
100°c |
10bar |
AD3160008 |
1-1/2″ F x 4 |
760mm |
6000 ltr/h |
YES |
104.4 |
100°c |
10bar |
AD3160007 |
2″ F x 4 |
910mm |
9000 ltr/h |
YES |
156.6 |
100°c |
10bar |